Laboratory

  • Asia AMCA counseled construction Fan performance and Reverberant Sound lab
  • ITRI counseled construction of high temperature lab
  • Facilities and equipment are designed in accordance with AMCA, EN, ISO and UL standard
  • Obtained ISO/IEC 17025: 2017 TAF lab accreditation in 2020 (accreditation no. 3652)

Service Highlights

  • Provide quality testing services
  • Technical support on product
  • Interlaboratory comparison

Testing Items

  • AMCA210 Fan performance test
  • AMCA300 Fan sound test
  • EN2101-3 Fan temp. test
  • UL555/555S Damper test
  • AMCA500D Damper test

Testing Capability

Fan Performance Test

  • Max. Airflow : 2500 cmm
  • Max. Pressure : 500 mmAq
  • AMCA 210 ISO 5801
  • Fig.12 Outlet Fig.15 Inlet

Reverberant Sound Test

  • AMCA 300
  • Fig. 2/ Fig. 3

High Temperature Test

  • Max. Temp. : 400℃
  • EN 12101-3 ISO 21927-3

Damper Testing

  • UL 555 Dynamic Closure
  • UL 555S AMCA 500D : Operation / Leakage